NE9-32S (1)

Easy to use controls with a bold illuminated LED display, offering precise temperature control from ambient +5°C to 100°C with timer function. Ideal for microbiology.

These digital scientific incubators can run at set temperature immediately, use run back timer or enable a delay start feature. Can be configured for gravity convection or with variable fan speed providing forced air circulation within the chamber.

The chamber is constructed from high quality stainless steel with high efficiency thermal insulation, contained within an outer steel housing with anti-bacterial paint finish.

With energy efficiency in mind, particular attention is paid to robust design, insulation, a tight door closure with silicone seal and hinge design, to maintain chamber temperatures with intelligent temperature control.

See the range of accessories compatible with the NE8 range.

2 Year Warranty

The NE8 Series comes with a 2 year warranty as standard, we also offer free advice and support for our incubators.

MADE IN GREAT BRITAIN

The NE8 Series is made here in Great Britain with the highest quality of materials.

Specifications

Product Code NE8-15S NE8-32S NE8-56S NE8-112S NE8-240S NE8-400S NE8-750S
Chamber Capacity 15 Litres 32 Litres 56 Litres 112 Litres 240 Litres 400 Litres 750 Litres
Temperature Range Ambient + 5°C - 100°C
Temperature Control PID Digital, LED display showing actual or set temperature, resolution 0.1°C
Temperature Alarm Over temperature alarm is automatically set 5°C above set point
Temperature Sensor pt100 with control diagnostics at power up
Temperature Fluctuation ±0.2°C at 37°C ±0.4°C at 37°C
Temperature Variation ±0.5°C at 37°C ±0.8°C at 37°C
Temperature Heat Up 37°C 10 Minutes 30 Minutes
Temp. Door Open Recovery 37°C 5 Minutes 10 Minutes
Temp. Control & Run Back Timer Visual indicator and end messaging 00:01 to 99:59 (hh:mm) activates at set temp
Temp Control & Delay Start Timer Heating commences at a set time in the future, within 24 hours
Chamber Convection Fan speed can be set from 0% gravity convection within the chamber variable to 100% for forced air convection
Exhaust Air Flap Adjustable 0 to 100% chamber venting
Access Port 35mm port size, perforated flap cover helps to reduce losses when fitting independent external probes or thermocouples
Doors Single insulated door, lockable with 2 point door engagement for an even seal Double insulated door, lockable with 2 point door engagement for an even seal
Door Alarm Door open, heating interrupted, delay before door sounder chimes until door closed, heating resumes
Shelves Fitted & Max. 1 wire / 3 max 2 wire / 5 max 2 wire / 8 max 3 wire / 10 max 3 wire / 14 max 5 wire / 16 max
Shelving Locations Available every 20mm vertically
Shelf Maximum Load 10 kg 20 kg
Heater Power (220-240V) 450W 1100W 2150W 2200W
Voltage 230V 50-60Hz
Stackable
Feet/Castors Levelling feet Levelling castors
Dimensions
External (mm) 520w x 390d x 600h 600w x 460d x 680h 600w x 605d x 720h 600w x 660d x 980h 800w x 720d x 1160h 1000w x 720d x 1470h 1240w x 810d x 1625h
Internal (mm) 320w x 180d x 240h 400w x 250d x 320h 400w x 400d x 360h 400w x 450d x 620h 600w x 510d x 800h 800w x 510d x 1040h 1040w x 600d x 1200h

Features and Benefits

Hotplate heat icon

Clifton incubators feature intuitive controls with a bold illuminated LED display, offering precise temperature control from ambient +5°C to 100°C with timer function.

Warranty icon

2 Year Warranty.

Serial no icon

Before leaving our factory every incubator is identified with a unique serial number and undergoes a factory calibration adjusting control to known traceable value. Electrically tested for safety at final inspection and a test certificate enclosed in rear of the instruction book.

Controller blue icon

Featuring bold illuminated LED display of measured temperatures in real-time, in increments of ±0.1°C with intuitive controls, utilising touch sensitive keypads. Indicators for heating, timer and alarm.

accessories icon

Broad range of accessories available to suit wide range of applications.

anti bac icon

The chamber is constructed from high quality stainless steel, with high efficiency thermal insulation, all contained within an outer steel housing with anti-bacterial paint finish.

Door Features

Door Configuration

Single insulated door, lockable with 2 point door engagement for an even seal. Double door on 400 and 750 litre incubators.

Door Alarm

Door open, heating interrupted, delay before door sounder chimes until door closed, heating resumes.

Safety Features

  • Switching on, the controls undergo an automatic diagnostic check.
  • Features a temperature sensor fail alarm with error reporting on LED screen.
  • Over temperature alarm is automatically set 5°C above set point.
  • Door open – heating is interrupted, after a short delay a door sounder chimes until door closed, heating resumes.
  • Fitted with Class 1 over temperature thermostat for overall unit protection.

Typical Applications

Clifton incubators are ideal for sample incubation at temperatures above ambient up to +100°C.

  • Incubation of samples for microbiological analysis
  • Analysis of thermal resistance of samples subjected to higher temperatures
  • Antibody testing
  • Bacteria testing
  • Crystallisation observations
  • Cultivation of thermophilic micro-organisms
  • Pharma stability tests
  • Food industry testing

Controls

Featuring bold illuminated LED display of measured temperatures in real-time, in increments of ±0.1°C with intuitive controls, utilising touch sensitive keypads. Indicators for heating, timer and alarm. Exhaust air flap is dial adjustable from 0 to 100% for chamber venting. Fan chamber convection variable from 0% to 100%. Fan convection improves temperature uniformity and heating recovery time. Door, lockable with 2 point door engagement for an even seal. The left hand side of the incubator features a 35mm diameter access port, with perforated flap cover, to reduce heat losses when used with external probes.

Notes

Before ordering please check the room or building access where this unit will be installed and electrical power requirements. Temperature fluctuation measurements are based on temperature readings on shelf in centre of the chamber. Incubators up to 112 litres are stackable. Do not place in direct sunlight or near a heat or cold source. Allow a 100mm air gap away from wall at rear.
Ensure there is a minimum 300mm air gap from top of the unit to ceiling.

ACCESSORIES

Wire Shelf
Product Code Incubator
WS-15
NE8-15S
WS-32
NE8-32S
WS-56
NE8-56S
WS-112
NE8-112S
WS-240
NE8-240S
WS-400
NE8-400S
WS-750
NE8-750S
Perforated Stainless Steel Wire Shelf
Product Code Incubator
SP-15
NE8-15S
SP-32
NE8-32S
SP-56
NE8-56S
SP-112
NE8-112S
SP-240
NE8-240S
SP-400
NE8-400S
SP-750
NE8-750S
Stainless Steel Test Tube Racks

Laboratory test tube rack, stainless steel 304 spec 18/8 non-magnetic, bright finish. Supplied flat packed ready for assembly. Can be cleaned with detergents, ultrasonics or autoclaved.

Product Code
6870 - (26 holes x 17mm diameter)
6871 - (16 holes x 26 mm diameter)
6872 - (36 holes x 13mm diameter)
6873 - (18 holes x 19mm diameter)
6900 - (12 holes x 32mm diameter)
Additional Program Function
Additional program functionality with temperature and time ramps. Factory installation at the time the model is ordered.
Product Code Incubator
RT-3
Available for all NE8 incubators
Factory Calibration 1 Point

1. Factory calibration record.

2. The completed calibration record will be enclosed at the rear of the instruction book accompanying the Clifton unit carrying the following information:

  • Unique record number for traceability.
  • Serial number of the unit.
  • Instrument it was checked against.
  • Calibration temperature and actual sensitivity results.

3. The measurement of uncertainty ±0.8°C. Ambient temperature 21°C ±3°C.

Notes:

A. The calibration record provides a measurement of precision about set point with maximum and minimum sensitivity readings obtained. Precision is defined as “(1) The ability of a measurement to be consistently reproduced” and “(2) The number of significant digits to which a value has been reliably measured”.

B. The calibration record does not provide or assures any form of accuracy. Accuracy is defined as “the ability of a measurement to match the actual value of the quantity being measured”.

Product Code Incubator
CAL
Available for all NE8 incubators
Temperature Survey 9 Point
1. Temperature survey chamber.
2. The completed calibration record will be enclosed at the rear of the instruction book accompanying the Clifton unit carrying the following information: Unique record number for traceability. Serial number of the unit. Instrument it was checked against. Calibration temperature and actual sensitivity results.
To be ordered with equipment.
Product Code Incubator
CAL-9
Available for all NE8 incubators
Temperature Survey 27 Point
1. Temperature survey chamber.
2. The completed calibration record will be enclosed at the rear of the instruction book accompanying the Clifton unit carrying the following information: Unique record number for traceability. Serial number of the unit. Instrument it was checked against. Calibration temperature and actual sensitivity results.
To be ordered with equipment.
Product Code Incubator
CAL-27
Available for all NE8 incubators

Downloads

Detailed document containing the specifications for the NE8 range.

Clifton® Clifton Range® Are registered trade marks of NICKEL-ELECTRO Ltd. Nickel-Electro Ltd. Oldmixon Crescent, Weston-super-Mare, North Somerset, BS24 9BL, UK.
This website and its contents are copyright Nickel-Electro Ltd 2023. All rights reserved. Terms and Conditions, Privacy Policy, Cookie Policy, Our Sustainability Pledge